CSA 221421
Ex ia IIC T3/T4 Ga
Ex ia I Ma
AEx ia IIC T3/T4
CLI Groups A, B, C, D
CLII Groups E, F, G; CLIII
CLI, Zone 0
Sira 15ATEX2152X
Ex ia IIC T3/T4 Ga
Ex ia I Ma
IECEx SIR 15.0060X
Ex ia IIC T3/T4 Ga
Ex ia I Ma
Operating Temp Code: T3
Ambient Temp Range = -40 to 121°C
Operating Temp Code: T4
Ambient Temp Range = -40 to 80°C
Control Drawing INS10012
Connector Exit Entity Parameters:
Ui = 28 Vdc, li = 120 mA, Pi = 1W, Ci = 0nF, Li = 0µH
Integral Cable Entity Parameters
Ui = 28 Vdc, li = 120 mA, Pi = 1W, Ci = 80.4nF, Li = 336µH
Requires one IS111-1B Intrinsic Safety Barrier